52.020 CONNECTION TO PUBLIC SEWER REQUIRED.
The owner of any house, building, or property. ..is hereby required at his expense to install suitable sanitary facilities therein. ..within 90 days after the date of official notice to do so, provided that said public sewer is accessible and available within 100 feet of said owners building, as determined by the Public Works Director.
Note: By definition, the "public sewer" is the main line of the sewer main.
52.122 SEPARATE CONNECTIONS
A separate and independent building connection shall be provided for every building except that when two or more buildings are so situated that a separate and independent building connection for each building would involve practical difficulties and impose unnecessary hardships, the Public Works Director may authorize the connection of such buildings to the public sewer through a single building connection, subject to such items and conditions of easement, design, and construction as he may require. In the case of multifamily, condominium, or town house dwelling units, each building connection will be subject to the issuance of a permit.
52.125 SIZE AND SLOPE
The size and slope of the building connection shall be subject to the approval of the Public Works Director, but in no event shall the diameter be less than four inches; and the slope of the four inch pipe shall in no case be less than Y4 inch per foot. Six inch pipe may be laid at a slope of 1/8 inch per foot. Pipe larger than the minimum size herein specified shall be used when and as the size of structure, numbers and kinds of fixtures to be drained or other conditions may make it necessary to provide for adequate and proper flow.
52.127 COVER AND ALIGNMENT.
The cover over the crown of the building connection shall be at least four feet to afford protection from frost action. Any deviation from the minimum cover required shall be done only with the written permission of the Public Works Director. The building connection shall be laid at a uniform grade and in straight alignment. Changes in direction shall be made only at clean outs or manholes as required by the Public Works Director. Clean outs shall be provided at maximum spacing of 75 feet on straight runs. (per Department policy, Clean outs are not allowed within the City's Right-of- Way).